CONFIDENTIAL [AK8999A/AW/AD]
MS1600-E-00 2014/05
- 65 -
b) OSC variable ratio storing register (Register name: CM2)
This register is used for adjustment of the oscillator frequency of AK8999A. The counted value in
the internal counter is stored. Since the internal counter is overflowing when a count value shows
FF hex, measure again by re-defining High level period.
This register is read only. In addition, the value of the register returns to the initial value on the
following conditions.
At the power up
When CM1 register is written
When CSCLK = Low is maintained 0.5msec or more
When ETST[0] is set to "L"
Address : 01 hex D[7:0] = CT[7:0]
(This is not a nonvolatile EEPROM, but a volatile register.)
CT[7:0] Count value Ratio
Description
Dec Hex Bin (time) (%)
0 00 00000000 0 0 Default
1 01 00000001 1 -99
98 62 01100010 98 -2
99 63 01100011 99 -1
100 64 01100100 100 0 Ideal value
101 65 01100101 101 1
102 66 01100110 102 2
254 FE 11111110 254 154
255 FF 11111111 - - Counter error