h) Pressure threshold detector 2 (EEPROM name: PTH2, HYS2)
The operating mode, the detection threshold values and the hysteresis voltage of the comparator for
the pressure threshold detector 2 are set up.
The detector threshold voltage and the hysteresis voltage vary ratiometrically with respect to the
supply voltage.
h.1) Pressure threshold detector operating mode setup
Address : 0A hex D[7:5] = EINV2[0], EINE2[0], EIN2L[0]
D[7:5] Symbol Mode setup
D[7] EINV2[0] Pressure threshold detector output polarity setup EEPROM
0 EINV21 High output when detected (default)
1 EINV20 Low output when detected
D[6] EINE2[0] Pressure threshold detector enabled setup EEPROM
0 INT2E Pressure threshold detector 2 enable (default)
1 INT2D Pressure threshold detector 2 disable
D[5] EIN2L[0] Pressure threshold detector 2 detection threshold setup EEPROM
0 INT2< Detect pressure above threshold (default)
1 INT2> Detect pressure below threshold
h.2) Pressure threshold detector detection threshold adjustment
Address : 0A hex D[4:0] = EPT2[4:0]
EPT2[4:0] Detection threshold (V)
Description
Dec Hex Bin Detect threshold ex. VDD:5V
-16 10 10000 0.900*VDD 4.500
-15 11 10001 0.875*VDD 4.375
-14 12 10010 0.850*VDD 4.250
: : : : :
-3 1D 11101 0.575*VDD 2.875
-2 1E 11110 0.550*VDD 2.750
-1 1F 11111 0.525*VDD 2.625
0 00 00000 0.500*VDD 2.500 Default
1 01 00001 0.475*VDD 2.375
2 02 00010 0.450*VDD 2.250
: : : : :
13 0D 01101 0.175*VDD 0.875
14 0E 01110 0.150*VDD 0.750
15 0F 01111 0.125*VDD 0.625
h.3) Comparator hysteresis voltage adjustment for pressure threshold detection
Address : 0B hex D[3:2] = EHYS2[1:0]
EHYS2[1:0] Hysteresis voltage (mV)
Description
Dec Hex Bin Hysteresis voltage ex. VDD:5V
2 2 10 0.030*VDD 150.0
3 3 11 0.040*VDD 200.0
0 0 00 0.050*VDD 250.0 Default
1 1 01 0.060*VDD 300.0